7. MAINTENANCE
7.1 Handling System Troubles
Fault What it means Solution
The control panel cannot configure or control
the device.
Battery consumption increases.
i) Make sure the device is physically present.
ii) Check the display for device faults, for
example, low battery.
iii) Use RF diagnostics to check the current
signal strength and during the last 24 hours.
iv) Open the device cover and replace the
battery or press the tamper switch.
v) Install the device in a different location.
vi) Replace the device.
A device was not installed or not installed
correctly, or, cannot establish communication
with the control panel after installation.
i) Make sure the device is physically present.
ii) Use RF diagnostics to check the current
signal strength and during the last 24 hours.
iii) Open the device cover and replace the
battery or press the tamper switch.
iv) Enroll the device again.
A device or detector has not reported for some
time to the control panel.
i) Make sure the device is physically present.
ii) Check the display for device faults, for
example, low battery.
iii) Use RF diagnostics to check the current
signal strength and during the last 24 hours.
iv) Replace the battery.
v) Replace the device.
A radio-frequency signal which is blocking
communication channel of sensors and control
panel is detected.
Locate the source of interference by switching
off any wireless devices (cordless telephones,
wireless ear plugs, etc.) in the house for 2
minutes then check if trouble continues.
Use also RF diagnostics to check signal
strength.
The battery in a sensor, keyfob or wireless
commander is near the end of its useful life.
i) For AC powered devices, check AC power is
available and connected to the device.
ii) Replace the device battery.
The fire detector must be cleaned Use a vacuum cleaner to clean the detector air
vents occasionally to keep them free of dust.
Gas detector failure Gas detector: Disconnect and then put back
the AC power supply connector
CO Gas detector: Replace the detector
There is no power to the siren Make sure that the AC power supply is
connected properly
There is no power to gas sensor Make sure that the AC power supply is
connected properly
The GSM communicator is not able to connect
to the cellular network.
i) Move the Panel and GSM unit to another
location.
ii) Enter and exit the installer menu
iii) Disconnect GSM unit and install it again
iv) Replace SIM card
v) Replace the GSM unit
The GSM communicator has detected that GSM
network signal is weak
Move the Panel and GSM unit to another
location.
There is no power and the system is working on
backup battery power
Make sure that the AC power supply is
connected properly
A
C SUPPLY FAILURE
R
SSI LOW
G
SM NET FAIL
A
C FAILURE
S
IREN AC FAILURE
G
AS TROUBLE
C
LEAN ME
L
OW BATTERY
J
AMMING
M
ISSING
N
OT NETWORKED
1
-
W
AY
Vista de página 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 77 78

Comentários a estes Manuais

Sem comentários