D-302756 45
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [09:EXIT MODE].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [09:EXIT MODE].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.8.2 Configuring Entry Delays Duration
Two different entry delays allow the user to enter the protected site (while the system is in the armed state) via 2 specific
doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-rate warning beeps start
sounding once the door is opened, until the last 10 seconds of the delay, during which the beeping rate increases.
Locations No. 1 (entry delay 1) and 2 (entry delay 2) allow you to program the length of these delays. Available options for
each delay are: "00s", "15s" (default for entry delay 2), "30s" (default for entry delay 1), "45s", "60s", "3m" and "4m".
Note: To comply with CP-01 requirements, "
00s
" and "
15s
" options are not available.
Note: To comply with EN requirements, the entry delay must not exceed 45 sec.
Note: To comply with UL requirements, the entry delay must not exceed 15 sec.
To Configure the Duration of the Entry Delays
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
Press the
button once for [02:ENTRY DELAY 2].
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [01:ENTRY DELAY 1].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
1:ENTRY DELAY 1
9:EXIT MODE
2:ENTRY DELAY 2
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
EADY 00:00
EFINE PANEL
9:EXIT MODE
1:ENTRY DELAY 1
NTER CODE:
EFINE PANEL
Comentários a estes Manuais