D-302756 41
Available options are: 00s (default in USA), 15s, 30s (default), 45s, 60s, 2m, 3m and 4m.
Note: To comply with CP-01 requirements, "60s", "3m" and "4m" options are not available.
Note: To comply with UL requirements, the abort time must not exceed 45 sec.
To Configure the Abort Time
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or buttons repeatedly and select the [DEFINE
PANEL] option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [05:ABORT TIME].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [05:ABORT TIME].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.7.7 Configuring a Confirmed Alarm
Here you determine that if 2 successive alarms will occur during a specific period, the second alarm will be considered as a
confirmed alarm for confirmed alarm reporting, (see par. 4.6.3.2 "Configuring the Event Types to be Reported").
Options: disable (default in USA), 30 min., 45 min., 60 min. (default), or 90 min.
To Configure a Confirmed Alarm
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or
button repeatedly until the display will read [33:CONFIRM TIME].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
OKI
SELECT OPTION
0
5:ABORT TIME
3
3:
C
ONFIRM
T
IME
0
1:ENTR
Y
DELAY 1
NTER CODE:
INSTALLER MODE
R
EADY 00:00
D
EFINE PANEL
0
5:
A
BORT TIME
0
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
R
EADY 00:00
D
EFINE PANEL
Vista de página 41