64 D-302756
[SHOW RF PROBLEMS].
3.
When the PowerMax10-G2 display reads [SHOW RF PROBLEMS], press the
OKI
button.
The PowerMax10-G2 display switches between the average signal strength
indications for the last 24 hours and between the current signal strength
indications of the first RF device type.∗
OKI
4.
Press the
button to view the signal strength indications for the next RF
device type.∗
The signal strength indications are as follows: "
STRONG
";
GOOD
";
POOR
,
BAD
;
"
BAD COM
" (poor communication is detected between the device and the control
panel); "
NO COM
." (no communication); "
NOT TST
" (results are shown without
any performed test); "
NOT NET
" (device is pre-enrolled – not networked);
"
NONE
" (keyfob 24Hr result); or "
EARLY
" (result of the last 24Hrs without
statistics).
∗
Pressing the
OKI
button will display the number and type of device to
which the signal strength indications refer.
Pressing the or buttons at any stage in the procedure will take
you to “
<OK> TO EXIT
”.
5.1.5 GPRS Communication Test
The GPRS Communication diagnostic procedure tests GSM/GPRS communication and reports the diagnostic result. In
case of communication failure, detailed information of the failure is reported.
1. Make sure the system is disarmed and then press the
button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
OKI
The screen will now prompt you to enter your installer code.
3.
Enter your Installer Code.
The PowerMax10-G2 display will read [NEW INSTL CODE].
CODE
4. When the PowerMax10-G2 display reads [NEW INSTL CODE] press the
or
button repeatedly until the PowerMax10-G2 display will read
[DIAGNOSTICS].
or
5. When the PowerMax10-G2 display reads [DIAGNOSTICS], press the
OKI
button.
The PowerMax10-G2 display will read [WL DEVICES].∗
OKI
6. When the PowerMax10-G2 display reads [WL DEVICES], press the
button.
The PowerMax10-G2 display will read [GSM/GPRS]
.
7.
When the PowerMax10-G2 display reads [GSM/GPRS], press the
OKI
button.**
OKI
8.
The PowerMax10-G2 display will read [PLEASE WAIT…] and will then
automatically change to read [UNIT IS OK].
See the table below for a complete list of possible GSM/GPRS messages.
∗ If there are no wireless devices enrolled in the PowerMax10-G2 system, the
PowerMax10-G2 display reads [
NO DEVICES
].
** When the
OKI
button is pressed the test result takes between 15 sec. to
4 min. before it is displayed, depending on the severity of the failure.
Pressing the or buttons at any stage in the procedure will take
NIT IS OK
LE
SE WAIT…
EW INSTL CODE
NTER CODE:
INSTALLER MODE
EADY 00:00
SM/GPRS
L DEVICES
IAGNOSTICS
01: NOW: NONE
01: 24hr: NONE
01 NOW: NO
TST
01: 24hr: GOOD
HOW RF PROBLEMS