The PowerMax10-G2 display will revert to [33:CONFIRM TIME].
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.7.8 Enable Alarm upon Detection of Jammed or Missing Device
Here you determine whether an alarm will be initiated (siren / report) when there is a supervision / jamming failure during
AWAY arming state.
Available options are: EN standard and other (default). When "EN standard" is selected, if there is supervision /
jamming failure during AWAY arming, the siren is activated and the events are reported as tamper events. When "Other"
is selected, there is no such activity during AWAY arming.
To Enable an Alarm Upon Detection of a Jammed or Missing Device
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read
[30:BELL/REP.OPT].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [30:BELL/REP.OPT].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.7.9 Configuring the Jamming Detection
Here you determine whether jamming (interfering transmissions, on the radio channel used by the system) will be detected
and reported or not.
If a jam detection option is selected, the system does not allow arming under the relevant jamming conditions.
Jam Detection Options
Option Detection and Reporting when
UL 20/20
(USA standard)
There is continuous 20 seconds of
jamming
EN 30/60
(Europe standard)
There is an accumulated 30 seconds of
jamming within 60 sec.
class 6 (30/60)
(British standard)
Like EN (30/60) but the event will be
reported only if the jamming duration
exceeds 5 minutes.
Disable (default) (No jamming detection and reporting).
3
0:BELL/REP.OPT
3
3:CONFIRM TIME
3
0:
B
ELL/REP.OPT
0
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
R
EADY 00:00
D
EFINE PANEL