82. Press the
OKI
button.
The PowerMax10-G2 display will revert to [AUTO TEST TIME].
OKI
83. Press the
button.
The PowerMax10-G2 display will read [AUTO TEST CYCLE]. Here you
determine the time interval between consecutive telephone line test messages
sent to the Monitoring Station. The control panel performs this at regular
intervals to verify proper communications.
84.
When the PowerMax10-G2 display reads [AUTO TEST CYCLE], press the
OKI
button.
The PowerMax10-G2 display will read [
test OFF ].
OKI
85. Press the or button repeatedly to select between "test OFF",
"
test every 1 d", "test every 2 d", "test every 5 d", "test every 7 d",
"
test every 14 d", "test every 30 d" and "test every 5 h", for example,
"
test every 5 d".
or
86. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [AUTO TEST CYCLE].
OKI
87. Press the button.
The PowerMax10-G2 display will read [LINE FAIL REPORT].
88. Press the
OKI
button.
The PowerMax10-G2 display will read [PSTN]. Here you determine if the PSTN
telephone line disconnection will be reported or not and determine the delay
between detection of line disconnection and the failure reporting. If the telephone
line is disconnected, the event "tel line fail" will be stored in the event log.
OKI
89. When the PowerMax10-G2 display reads [PSTN], press the
OKI
button.
The PowerMax10-G2 display will read [
immediately ].
OKI
90. Press the or button repeatedly to select between
"
immediately", "5 minutes", "30 minutes", "60 minutes", "180 minutes"
and "
don't report", for example, "60 minutes".
or
91. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [PSTN].
OKI
92. Press the button.
The PowerMax10-G2 display will read [GSM/GPRS]. Here you determine if the
GSM/GPRS line disconnection will be reported or not and determine the delay
between detection of line disconnection and report failure. If the telephone line
is disconnected, the event "GSM line fail" will be stored in the event log.
93. Press the
OKI
button.
The PowerMax10-G2 display will read [
don't report ].
OKI
94. Press the or button repeatedly to select between "2 minutes",
"
5 minutes", "30 minutes", "60 minutes", "180 minutes" and "don't
report", for example, "30 minutes".
or
95. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [GSM/GPRS].
OKI
96. Press the button.
G
SM/GPRS
P
STN
A
UTO TEST CYCLE
d
on't report
G
SM/GPRS
immediately
P
STN
L
INE FAIL REPORT
t
est OFF
A
UTO TEST CYCLE
A
UTO TEST TIME
3
0 minutes
30 minutes
6
0 minutes
60 minutes
t
est every 5 d
test every 5 d