D-302756 33
The PowerMax10-G2 display will read [broadband]. Here you determine if the
Broadband Module line disconnection will be reported or not and determine the
delay between detection of line disconnection and report failure. If the telephone
line is disconnected, the event "BBA line fail" will be stored in the event log.
97. Press the
OKI
button.
The PowerMax10-G2 display will read [
don't report ].
OKI
98. Press the or button repeatedly to select between "2 minutes",
"
5 minutes", "30 minutes", "60 minutes", "180 minutes" and "don't
report", for example, "30 minutes".
or
99. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [broadband].
OKI
100.
Press the
button.
The PowerMax10-G2 display will revert to [LINE FAIL REPORT].
You can now press the button to take you to the "
PSTN UP/DOWN
" menu
(see Configuring Remote Programming Access Permissions), or press the
button to take you to "
<OK> TO EXIT
".
4.6.3.8 Configuring the Event Types to be Reported to the Monitoring Station
Continue below from the previous section or repeat steps 1 to 7 of section 4.6.3.1and then press the or
button repeatedly until the PowerMax10-G2 display will read [AUTO TEST TIME]
101. Press the
button.
The PowerMax10-G2 display will read [RPRT CNFRM ALARM]. Here you
determine whether the system will report whenever 2 or more events
(confirmed alarm) occur during a specific period.
102. Press the
OKI
button.
The PowerMax10-G2 display will read [disable report].
OKI
103. Press the or button repeatedly to select between
"
disable report", "enable + bypass" and "enable report", for example,
"
enable report".
or
104. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [RPRT CONFRM ALARM].
OKI
105. Press the button.
The PowerMax10-G2 display will read [RECENT CLOSE]. Here you enable or
disable the “recent closing” report, that is sent to the Monitoring Station if an alarm
occurs within 2 minutes from the expiry of the exit delay.
106. When the PowerMax10-G2 display reads [RECENT CLOSE], press the
OKI
button.
The PowerMax10-G2 display will read [recent cl. OFF
].
OKI
107. Press the or button to select between "recent cl. OFF" and
"recent cl. ON", for example, "recent cl. ON".
or
108. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [RECENT CLOSE].
OKI
R
ECENT CLOSE
R
PRT CONFRM ALARM
b
roadband
r
em. access OFF
r
ecent cl. ON
r
ecent
c
l. OFF
R
ECENT CLOSE
e
nable report
enable report
d
isable report
R
PRT CNFRM ALARM
L
INE FAIL REPORT
b
roadband
d
on't report
3
0 minutes
30 minutes