D-302756 25
communication, or, temporarily connected to receive event reports only.
55.
When the PowerMax10-G2 display reads [
SESSION TIMEOUT], press
OKI
.
The PowerMax10-G2 display will read [
off on timeout
].
OKI
56.
Press the
or button to select between "off on timeout"
and "always ON", for example, "always ON ".
or
57. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [
SESSION TIMEOUT].
OKI
You can now press the button to take you to the "
GPRS REPORT
" menu
(see section 4.6.2.1), or press the button to take you to "
<OK> TO EXIT
".
Key Functionality
Moves the cursor from left to right.
Long press for speed.
Moves the cursor from right to left.
Long press for speed.
Scrolls upward the sequence of inserted digits.
Long press for speed.
Scrolls downward the sequence of inserted digits.
Long press for speed.
Places cursor to extreme right position of edit string and shows the last 16 digits of edit string.
Reverts to previous or top menu without saving the edit string.
Reverts to "<OK> TO EXIT" without saving the edit string.
OK
I
Saves and reverts to previous menu.
Clears all digits to the right of cursor.
Clears one digit by cursor.
Selects between uppercase or lowercase digits.
4.6.3 Configuring Event Reporting to Monitoring Station.
Here you determine which types of event will be reported to Monitoring Stations. Due to lack of space in the display,
abbreviations are used: alarm is “alrm”, alert is “alrt” and open/close is “o/c”. The asterisk (J) is a separator between
events reported to Monitoring Station 1 and events reported to Monitoring Station 2.
Messages are divided by type into the following groups:
Group Abbr. Events Reported
Alarms alrm Fire, Burglary, Panic, Tamper
Open/close o/c Arming AWAY, Arming HOME, Disarming
Alerts Alrt No-activity, Emergency, Latchkey, Gas, Flood,
Temperature
Maintenance - Low-battery AC failure
"Alarm" group has the highest priority and "Alert" group has the lowest priority.
The selectable options are as follows:
Plan name Sent to center 1 Sent to center 2
"all -o/c J backup" All but open/close
All but open/close if center 1 doesn’t respond
"all J all" All All
"all-o/c J all -o/c " All but open/close All but open/close
"all –o/c J o/c " All but open/close Open/close
"all (–alrt) J alrt" All but alerts Alerts
"alrm J all (–alrm)" Alarms All but alarms
"disable report" Nothing Nothing
"all J backup" All All if cent. 1 doesn’t respond
Note: “All” means that all 4 groups are reported and also trouble messages - sensor / system low battery, sensor inactivity,
power failure, jamming, communication failure etc.
ESSIO
TIMEOUT
lways ON
lways ON
off on timeout