D-302756 31
The PowerMax10-G2 display will read [
4 attempts ].
69. Press the or button repeatedly to select between "2
attempts", "4 attempts", "8 attempts", "12 attempts" and "16
attempts", for example, "12 attempts".
or
70. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [PSTN RPRT RETRY].
OKI
71. Press the button.
The PowerMax10-G2 display will read [GSM RPRT RETRY]. Here you determine
the number of times the communicator will try to report via a cellular group
(GPRS, GSM and SMS) to the Monitoring Station.
72.
When the PowerMax10-G2 display reads [GSM RPRT RETRY], press the
OKI
button.
The PowerMax10-G2 display will read [
4 attempts ].
OKI
73. Press the or button repeatedly to select between
"
2 attempts", "4 attempts", "8 attempts", "12 attempts" and "16 attempts",
for example, "12 attempts".
or
74. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [GSM RPRT RETRY].
OKI
75. Press the button.
The PowerMax10-G2 display will read [LAN RPRT RETRY]. Here you determine
the number of times the communicator will try to report via the Broadband
Module communication to the Monitoring Station.
76.
When the PowerMax10-G2 display reads [LAN RPRT RETRY], press the
OKI
button.
The PowerMax10-G2 display will read [
4 attempts ].
OKI
77. Press the or button repeatedly to select between "2
attempts", "4 attempts", "8 attempts", "12 attempts" and "16
attempts", for example, "12 attempts".
or
78. Press
OKI
to confirm the selection.
The PowerMax10-G2 display will revert to [LAN RPRT RETRY].
OKI
You can now press the button to take you to the "
AUTO TEST TIME
"
menu, or press the button to take you to "
<OK> TO EXIT
".
4.6.3.7 Configuring the Auto Test Report
Continue below from the previous section or repeat steps 1 to 7 of section 4.6.3.1and then press the or
button repeatedly until the PowerMax10-G2 display will read [AUTO TEST TIME]
79. Press the
button.
The PowerMax10-G2 display will read [AUTO TEST TIME]. Here you determine
the time at which the telephone line will be tested and reported to the Monitoring
Station.
80.
When the PowerMax10-G2 display reads [AUTO TEST TIME], press the
OKI
button.
OKI
81.
Enter the auto test time.
AN RPRT RETRY
SM RPRT RETRY
STN RPRT RETRY
UTO TEST TIME
attempts
AN RPRT RETRY
attempts
SM RPRT RETRY
attempts
test time 12:00P
12 attempts
12 attempts
12 attempts
12 attempts
12 attempts
12 attempts