Visonic PowerMax10 Especificações Página 63

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 78
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 62
62 D-302756
The diagnostic test process is shown below.
5.1 Testing Devices
This section describes how to test or review a device enrolled to the PowerMax10-G2 control panel.
Note:
It is much easier to test the device while holding the device in your hand, close to the control panel.
5.1.1 Testing all Devices
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
OKI
The screen will now prompt you to enter your installer code.
3.
Enter your Installer Code.
The PowerMax10-G2 display will read [NEW INSTL CODE].
CODE
4. When the PowerMax10-G2 display reads [NEW INSTL CODE] press the
or
button repeatedly until the PowerMax10-G2 display will read
[DIAGNOSTICS].
or
5. When the PowerMax10-G2 display reads [DIAGNOSTICS], press the
OKI
button.
The PowerMax10-G2 display will read [WL DEVICES].
OKI
6. When the PowerMax10-G2 display reads [WL DEVICES], press the
OKI
button.
The PowerMax10-G2 display will read [TEST ALL DEVICES]
.
OKI
7.
When the PowerMax10-G2 display reads [TEST ALL DEVICES], press the
OKI
button (or press the button for [TEST ONE DEVICE]).
OKI
The PowerMax10-G2 system will now perform automatic testing of all enrolled
devices in the following order: repeaters, sirens, detectors, keypads.
The PowerMax10-G2 system will perform automatic testing of keyfobs (if
enrolled) at the end of testing all other devices.
Note: "Zxx" indicates the type of device and device number that is being
tested. "NNN" indicates the number of devices that have not yet been tested.
At this stage if any key is pressed the PowerMax10-G2 display will read
[
<NEXT> TO END
] alternating with [
<OK> TO CONTINUE
]. Press the
button to stop the current test and jump to the next test, or, press the
OKI
button to continue the test, or, press the button to exit.
At the end of the testing procedure the PowerMax10-G2 display will read [
SHOW
ALL DEVICES
].
If there are no wireless devices enrolled in the PowerMax10-G2 system, the
PowerMax10-G2 display reads [
NO DEVICES
].
Pressing the or buttons at any stage in the procedure will take
you to "
<NEXT> TO END
" or “
<OK> TO EXIT
”.
or
5.1.2 Testing One Device
1.
Repeat steps 1 to 6 from section 5.1.1 Testing all Devices.
2.
When the PowerMax10-G2 display reads [TEST ALL DEVICES], press the
button.
The PowerMax10-G2 display will read [TEST ONE DEVICE]
.
3.
When the PowerMax10-G2 display reads [TEST ONE DEVICE], press the
OKI
button.
T
EST ALL DEVICES
N
EW INSTL CODE
NTER CODE:
INSTALLER MODE
R
EADY 00:00
A
CTIVATE NOW Uxx
T
EST KEYFOBS NN
T
ESTING Zxx NNN
T
EST ONE DEVICE
T
EST ALL DEVICES
W
L DEVICES
D
IAGNOSTICS
Vista de página 62