D-302756 47
or
button repeatedly until the display will read [07:QUICK ARM].
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [07:QUICK ARM].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.8.5 Configuring Bypassing Zones
Here you permit either manual bypassing of individual zones (through the USER SETTINGS menu), or allow the system to
"force arm" (perform automatic bypassing) of open zones during the exit delay. If desired, press the arming key again if you
want to eliminate the protest tone that sounds during forced arming. If a zone is open and forced arming is not permitted,
“NOT READY” is displayed and the system does not arm (the “Sad Melody” will sound). If "no bypass" is selected, neither
manual bypassing nor force arming is allowed.
Options: manual bypass (default in USA), force arm and no bypass (default).
Note: To comply with EN requirements, "manual bypass" or "force arm" must be selected.
Note: The option "force arm" is not applicable in the UK.
To Configure Bypass
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2. When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [08:BYPASS].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [08:BYPASS].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.8.6 Configuring Panic Alarm Activation
Here you determine whether the user will be allowed to initiate a panic alarm by simultaneous pressing of either the two
panic buttons (on the keypad / wireless commander) or away + home (on a keyfob transmitter). Audible panic activates the
siren and simultaneously transmits a message via telephone. Silent panic only transmits a message via telephone.
The options are: silent panic, audible panic (default) and disable panic.
To Configure Panic Alarm Activation
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
8:BYPASS
7:QUICK ARM
EADY 00:00
8:
YPASS
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
EADY 00:00
EFINE PANEL
7:
UICK ARM
Comentários a estes Manuais