D-302756 63
The first device type is displayed, "CONTACT SENSORS".
OKI
4.
Press the
or button repeatedly to select between "CONTACT
SENSORS", "MOTION SENSORS", "SMOKE SENSORS", "KEYFOBS", "SIRENS" or
"REPEATERS", for example, "MOTION SENSORS".
or
5.
After making your selection, press the
OKI
button.
The PowerMax10-G2 display will read the device name alternating with the
location.
OKI
6.
Press the
OKI
button. The PowerMax10-G2 display will read [TESTING Zxx
001] or [ACTIVATE NOW Uxx] for keyfobs.
OKI
After testing the PowerMax10-G2 display will then automatically change to read
the average level for the last 24 hours (for stationary devices) or the number of
activations that the control panel has received (for keyfobs).
The signal strength indications are as follows: "
STRONG
";
GOOD
"; "
POOR
";
"
BAD
"; "
BAD COM
" (poor communication is detected between the device and the
control panel); "
NO COM
." (no communication); "
NOT TST
" (results are shown
without any performed test); "
NOT NET
" (device is pre-enrolled – not
networked); "
NONE
" (keyfob 24Hr result); or "
EARLY
" (result of the last 24Hrs
without statistics).
Pressing the or buttons at any stage in the procedure will take
you to “
<OK> TO EXIT
”.
or
5.1.3 Displaying Signal Strength Indication of All Devices
1.
Repeat steps 1 to 6 from section 5.1.1 Testing all Devices.
2.
When the PowerMax10-G2 display reads [TEST ALL DEVICES], press the
and buttons repeatedly until the PowerMax10-G2 display will
read [SHOW ALL DEVICES].
or
3.
When the PowerMax10-G2 display reads [SHOW ALL DEVICES], press the
OKI
button.
The PowerMax10-G2 display switches between the average signal strength
indication for the last 24 hours and between the current signal strength
indications of the first device type.∗
OKI
4.
Press the
button to view the signal strength indications for the next
device type.∗
The signal strength indications are as follows: "
STRONG
";
GOOD
"; "
POOR
"; "
BAD
";
"
BAD COM
" (poor communication is detected between the device and the control
panel); "
NO COM
." (no communication); "
NOT TST
" (results are shown without
any performed test); "
NOT NET
" (device is pre-enrolled – not networked);
"
NONE
" (keyfob 24Hr result); or "
EARLY
" (result of the last 24Hrs without
statistics).
∗
Pressing the
OKI
button will display the number and type of device to
which the signal strength indications refer.
Pressing the or buttons at any stage in the procedure will take
you to “
<OK> TO EXIT
”.
5.1.4 Displaying Signal Strength Indication of RF Devices
1.
Repeat steps 1 to 6 from section 5.1.1 Testing all Devices.
2.
When the PowerMax10-G2 display reads [TEST ALL DEVICES], press the
or button repeatedly until the PowerMax10-G2 display will read
or
EST ALL DEVICES
01: NOW: NONE
01: 24hr: N
NE
01 NOW: NOT TST
01: 24hr: GOOD
EST ALL DEVICES
HOW ALL DEVICES
OTION SENSORS
ONTACT SENSORS
CTIVATE NOW Uxx
01 24Hr: EARLY
01 NOW: STRONG
ESTING Zxx 001
ront door