66 D-302756
The following LAN messages are reported:
Message Description
Unit is ok Broadband Module is functioning correctly.
Test aborted The diagnostic test is aborted, as follows:
• AC failure – Broadband Module is set to OFF mode.
• Broadband Module has not completed the power-up procedure. In this case, the
installer should wait a maximum of 30 seconds before re-testing.
Comm. loss The RS-232 serial interface between the Broadband Module and the PowerMax10-G2
failed.
Rcvr Ip missing Receivers IP 1 and 2 settings are missing in the PowerMax10-G2.
Cable unplugged The Ethernet cable is not connected to the Broadband Module.
Check lan config This message appears in any of the following cases:
• Incorrect Broadband Module IP has been entered.
• Incorrect subnet mask has been entered.
• Incorrect default gateway has been entered.
• DHCP server failure.
Rcvr#1 UnReach.
Rcvr#2 UnReach.
Receiver 1 or 2 is inaccessible, as follows:
• Wrong receiver IP has been entered.
• Receiver failure.
• WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMax10-G2 unit is not registered to IP receiver 1 or 2.
Broadband Module timeout
err.
Broadband Module does not respond to test result within 70 sec.
Invalid result Broadband Module responds with a result code that is not recognized by the
PowerMax10-G2.
5.1.7 LAN Reset Option
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
OKI
The screen will now prompt you to enter your installer code.
3.
Enter your Installer Code.
The PowerMax10-G2 display will read [NEW INSTL CODE].
CODE
4. When the PowerMax10-G2 display reads [NEW INSTL CODE] press the
or
button repeatedly until the PowerMax10-G2 display will read
[DIAGNOSTICS].
or
5. When the PowerMax10-G2 display reads [DIAGNOSTICS], press the
OKI
button.
The PowerMax10-G2 display will read [WL DEVICES].∗
OKI
6. When the PowerMax10-G2 display reads [WL DEVICES], press the or
button repeatedly until the PowerMax10-G2 display will read [LAN
RESET OPTION].
or
7.
When the PowerMax10-G2 display reads [LAN RESET OPTION], press the
OKI
button.
OKI
8.
The PowerMax10-G2 display will read [REBOOT].
To reset the broadband module
9.
Press the
OKI
button.
The PowerMax10-G2 display will revert to [REBOOT].
OKI
To reset all LAN setting definitions (does not reset Monitoring Station IP definitions)
EBOOT
EBOOT
EW INSTL CODE
NTER CODE:
INSTALLER MODE
EADY 00:00
AN RESET OPTION
L DEVICES
IAGNOSTICS