6 D-304271 PowerMaster-10/30 G2 Addendum
Using the User Code
This section is an update to the PowerMaster-10/30 G2 User's Guide – Chapter 9 "Testing the System".
A. To Enter the Periodic Test Menu
1.
Make sure the system is disarmed and then press the button repeatedly
until the display reads "PERIODIC TEST" and press to confirm.
1
2.
The screen will now prompt you to enter your user code.
2
3.
CODE
Enter your User Code.
2
3
Go to step 4
B. To Test the Sirens
4.
The display now reads [SIRENS TEST].
5.
To initiate the siren test press .
Immediately after pressing , all 4
LED's on the panel should light (LED test).
4
The display now reads [SIREN N], where "N" indicates the zone location assigned
to the siren that is currently being tested.
5
First the panel siren sounds for 3 seconds after which the PowerMaster system
will automatically repeat the procedure for the next siren enrolled in the system
until all sirens are tested.
6
You should listen to the sirens sounds and make sure that all sirens sound.
Once all the sirens have been tested, the control panel will now test the sirens of
smoke sensors that are enrolled in the alarm system. The display now reads [Zxx:
SMOKE SIREN], where "Zxx" indicates the zone number of the smoke sensor,
and alternates with [<OK> TO CONTINUE]. During this time, the siren of the
tested smoke sensor will sound for up to one minute.
Press to test the siren of the next smoke sensor.
6.
or
When all the sirens test is complete, the display reads [SIREN TESTS END].
Press the or the button to confirm the test and then move to the
next step for zone temperature display.
Additional Information (Periodic Test)
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication see PowerMaster Installer's Guide.
4
To skip the SIRENS TEST and select the other devices TEST, press .
5
If the panel's display reads "SIREN P", this indicates that the control panel's siren is currently being tested.
6
The Periodic test can be performed on a maximum of two wireless sirens (including one internal siren) and
the sirens of enrolled smoke sensors. Outdoor sirens are activated with low volume.
VISONIC LTD. 2012
POWERMASTER-10/30 G2 v15 ADDENDUM D-304271 Rev 0 (09/12)
READY 00:00
PERIODIC TEST
ENTER CODE:
SIRENS TEST
SIRENS TESTS END
SIREN N