5. PROGRAMMING
D-304762 PowerMaster-10/30 G2 Installer's Guide
53
Option Configuration Instructions
3rd e-mail
→
→→
→
4th e-mail
→
→→
→
1st MMS tel #
→
→→
→
2nd MMS tel #
→
→→
→
3rd MMS tel #
→
→→
→
4th MMS tel #
To program:
Press to enter the "IMAGE FORWARD" sub menu and then select and program each of
the four e-mail numbers and then each of the four mobile phone numbers. When done, press
to return.
Enter the 1
st
, 2
nd
, 3
rd
and 4
th
e-mail addresses (see note below) then enter the 1
st
, 2
nd
, 3
rd
and
4
th
mobile phone numbers ("1st MMS tel #" etc.)
Note: To enter the e-mail addresses, to move the cursor and clear digits, use the "String
Editor's" keys as described in the table at the end of section 5.6.3.
VIEW ON DEMAND
By enabling the "On Demand View", you can determine during which arming modes (system
states) the "On Demand View" will be permitted. In the next option "VIEW TIME WINDOW"
you can determine when, during the permitted arming modes, the "On Demand View"
will be
enabled.
Options: disabled (default); in all modes; in AWAY only; in HOME only; in HOME &
AWAY; DISARM & AWAY; DISARM & HOME; and in DISARM only.
VIEW TIME WINDOW
menu appears only if
an option other than
"Disabled" is selected in
“VIEW ON DEMAND”
If the "On Demand View" is enabled in the previous option, you can further determine whether
the "On Demand View" will be possible at any time during the selected arming modes (i.e.
"Always") or restricted only to a specific limited time window that follows an alarm event.
Options: Always (default); Alarm + 5 min.; Alarm + 15 min.; Alarm + 1 hour
VIEW OTHER ALARM
Define whether the system will capture and forward image clips also upon occurrence of Non-
Burglary alarms (i.e. Fire, Duress, Emergency and panic).
Options: Enable (default); Disable.
5.6.7 Configuring Upload / Download Remote Programming Access Permission
Using a PC computer, the PowerMaster can be configured (by upload/download) either locally or from remote via
PSTN telephone line or GPRS cellular communication.
Note: For UL installations, do not enable Remote Programming via GPRS.
Local programming can be performed by direct connecting the computer to the panel's serial port using the Remote
Programmer PC Software.
Remote programming via PSTN can be performed by using a modem and the same software. The modem dials to
the control panel and establishes a connection via PSTN using an agreed process. When connection is established,
the installer or Master installer can access the panel using the UL/DL access codes programmed in the
"PSTN UP/DOWNLOAD" menu – see table below. For further information refer to the "PowerMaster Remote
Programmer Software User's Guide".
Remote programming via GPRS is performed using a Visonic PowerManage server and related Remote Programmer
PC software. The PowerManage server calls from a cellular modem to the Panel's SIM card number. The panel checks
the caller ID and if identical with any of the two callers ID 1 or 2 programmed in the "GPRS UP/DOWNLOAD" menu
(see table below), the panel initiates a GPRS connection with the respective IP Receiver 1 or 2 (as configured in
section 5.6.4 options 21 & 22). When connection is established, the monitoring company can perform the
upload/download procedure via the established secured GPRS connection. For further information refer to the
PowerManage User's Guide
In this section you can configure the access permissions (i.e. security codes and identification) and determine the
functionality of the upload/download procedures via PSTN and GPRS channels.
04:COMMUNICATION
⋅ ⋅ ⋅
6:UP/DOWNLOAD
⋅ ⋅ ⋅
MENU you wish
Enter "6:UP/DOWNLOAD", select the menu to configure (see guidance above and in section 5.6.1), then refer to the
table below for configuration instructions.
Option Configuration Instructions
PSTN UP/DOWNLOAD
Configure the Upload/Download functionality via PSTN. The functionality is determined
through a sub-menu of the "PSTN UP/DOWNLOAD" option as shown below.