Visonic POWERMASTER-10 Guia do Utilizador Página 1

Consulte online ou descarregue Guia do Utilizador para Sistemas de segurança - controlo de acesso Visonic POWERMASTER-10. Visonic POWERMASTER-10 User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 96
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
D-304762 PowerMaster-10/30 G2 Installer's Guide 1
PowerMaster-10/30 G2
Version 17
Installer and Quick User Guide
Table of Contents
1. INTRODUCTION ................................................... 3
1.1 System Features ............................................ 3
2. CHOOSING THE INSTALLATION LOCATION ... 7
3. POWERMASTER-10 G2 INSTALLATION ........... 8
3.1 Opening the PowerMaster-10 G2 Control
Panel and Bracket Mounting .............................. 8
3.2 Connecting to the Telephone Line ............... 9
3.3 System Planning & Programming .............. 10
3.4 GSM Module Installation ............................. 10
3.5 PGM-5 Installation ....................................... 11
3.6 Adding Wired Zones or PGM Device ......... 12
3.7 Connecting Power to the Control Panel .... 14
3.8 Supplying Power to the Unit ....................... 16
3.9 Closing the PowerMaster-10 G2 Control
Panel ................................................................... 16
4. POWERMASTER-30 G2 INSTALLATION ......... 17
4.1 PowerMaster-30 G2 Wiring Diagram .......... 17
4.2 Opening the PowerMaster-30 G2 Control
Panel and Bracket Mounting ............................ 18
4.3 Connecting to the Telephone Line ............. 18
4.4 Connecting Wired Zone and Siren ............. 19
4.5 System Planning & Programming .............. 19
4.6 GSM Module Installation ............................. 20
4.7 DUAL RS-232 Optional Module Mounting . 20
4.8 PGM-5 Installation ....................................... 21
4.9 Optional Expander Module ......................... 22
4.10 Connecting Power to the Control Panel .. 24
4.11 Battery Insertion ........................................ 25
4.12 Supplying Power to the Unit ..................... 26
4.13 Closing the PowerMaster-30 G2 Control
Panel ................................................................... 26
5. PROGRAMMING ................................................ 27
5.1 General Guidance ........................................ 27
5.1.1 Navigation ................................................ 27
5.1.2 Feedback Sounds .................................... 27
5.2 Entering the "Installer Mode" and Selecting
a Menu Option ................................................... 28
5.2.1 Entering the "Installer Mode" if "User
Permit" is enabled ............................................. 28
5.2.2 Selecting options ..................................... 28
5.2.3 Exiting the Installer Mode ........................ 28
5.3 Setting Installer Codes ............................... 29
5.3.1 Identical Installer and Master Installer
Codes ............................................................... 30
5.4 Zones / Devices ........................................... 30
5.4.1 General Guidance & Zones/Devices Menu
Options ............................................................. 30
5.4.2 Adding New Wireless Devices or Wired
Sensors ............................................................. 30
5.4.3 Deleting a Device ..................................... 34
5.4.4 Modifying or Reviewing a Device ............. 34
5.4.5 Replacing a Device .................................. 34
5.4.6 Defining Configuration Defaults for "Device
Settings" ............................................................ 35
5.4.7 Configuring Soak Test Mode ................... 36
5.4.8 Updating Devices after Exiting Installer
Mode ................................................................. 36
5.5 Control Panel ............................................... 36
5.5.1 General Guidance "Control Panel" Flow-
Chart & Menu Options ...................................... 36
5.5.2 Configuring Arming/Disarming and
Exit/Entry Procedures ....................................... 37
5.5.3 Configuring Zones Functionality .............. 39
5.5.4 Configuring Alarms & Troubles ................ 40
5.5.5 Configuring Sirens Functionality .............. 41
5.5.6 Configuring Audible & Visual User Interface
.......................................................................... 42
5.5.7 Configuring Jamming and Supervision
(Missing device) ................................................ 43
5.5.8 Configuring Miscellaneous Features ....... 44
5.6 Communication ........................................... 44
5.6.1 General Guidance "Communication" Flow-
Chart & Menu Options ........................................ 44
5.6.2 Configuring PSTN (landline phone)
Connection ........................................................ 46
5.6.3 Configuring GSM-GPRS (IP) - SMS
Cellular Connection .......................................... 47
Vista de página 0
1 2 3 4 5 6 ... 95 96

Resumo do Conteúdo

Página 1 - Version 17

D-304762 PowerMaster-10/30 G2 Installer's Guide 1 PowerMaster-10/30 G2 Version 17 Installer and Quick User Guide Table of Contents 1. INTRODUC

Página 2

3. POWERMASTER-10 G2 INSTALLATION 10 D-304762 PowerMaster-10/30 G2 Installer's Guide 3.3 System Planning & Programming Program the system now

Página 3 - 1. INTRODUCTION

3. POWERMASTER-10 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 11 3.5 PGM-5 Installation PGM-5 is an output interface module d

Página 4

3. POWERMASTER-10 G2 INSTALLATION 12 D-304762 PowerMaster-10/30 G2 Installer's Guide 3.6 Adding Wired Zones or PGM Device Required tools: Cutter

Página 5

3. POWERMASTER-10 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 13 PGM AND ZONE WIRING A. PGM output** Vmax=30v Imax=100mA

Página 6

3. POWERMASTER-10 G2 INSTALLATION 14 D-304762 PowerMaster-10/30 G2 Installer's Guide 3.7 Connecting Power to the Control Panel CONNECTING AC POWE

Página 7

3. POWERMASTER-10 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 15 CONNECTING AC POWER USING INTERNAL AC/DC POWER SUPPLY UNIT P

Página 8

3. POWERMASTER-10 G2 INSTALLATION 16 D-304762 PowerMaster-10/30 G2 Installer's Guide 3.8 Supplying Power to the Unit Connect power to the PowerM

Página 9 - Figure 3.2 –Phone Wiring

4. POWERMASTER-30 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 17 4. POWERMASTER-30 G2 INSTALLATION Required tool: Philips sc

Página 10 - 3.4 GSM Module Installation

4. POWERMASTER-30 G2 INSTALLATION 18 D-304762 PowerMaster-10/30 G2 Installer's Guide 4.2 Opening the PowerMaster-30 G2 Control Panel and Bracket

Página 11 - 3.5 PGM-5 Installation

4. POWERMASTER-30 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 19 PHONE WIRING IN NORTH AMERICA A. LINE B. SET C. RJ-31X

Página 12 - Figure 3.6a – Cable Wiring

2 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.6.4 Configuring Events Reporting to Monitoring Stations ...

Página 13 - PGM: not to be enabled in UL

4. POWERMASTER-30 G2 INSTALLATION 20 D-304762 PowerMaster-10/30 G2 Installer's Guide 4.6 GSM Module Installation (detail "N" in Figur

Página 14 - Connection

4. POWERMASTER-30 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 21 1. To install the DUAL RS-232 module into the control panel

Página 15

4. POWERMASTER-30 G2 INSTALLATION 22 D-304762 PowerMaster-10/30 G2 Installer's Guide A. PowerMaster-30 G2 connector B. Front unit C. PGM-5 M

Página 16 - Figure 3.9 - Final Closure

4. POWERMASTER-30 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 23 OPTIONAL EXPANDER MODULE, ZONES, SIRENS, AUDIO BOX AND WIRED

Página 17

4. POWERMASTER-30 G2 INSTALLATION 24 D-304762 PowerMaster-10/30 G2 Installer's Guide The 12V and "GND" terminals can be connected to a

Página 18 - Figure 4.3a – Phone Wiring

4. POWERMASTER-30 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 25 3. Insert the power cable through the desired wiring channe

Página 19

4. POWERMASTER-30 G2 INSTALLATION 26 D-304762 PowerMaster-10/30 G2 Installer's Guide 4.12 Supplying Power to the Unit Connect power to the PowerM

Página 20 - 4.6 GSM Module Installation

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 27 5. PROGRAMMING 5.1 General Guidance This chapter explains the Installer program

Página 21 - 4.8 PGM-5 Installation

5. PROGRAMMING 28 D-304762 PowerMaster-10/30 G2 Installer's Guide You can control the volume level of the sounded beeps by pressing the button o

Página 22 - Figure 4.9a –Expander Module

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 29   – Exiting the Installer Mode [1] To exit "INSTALLER MODE", move

Página 23 - and Siren Wiring

1. INTRODUCTION D-304762 PowerMaster-10/30 G2 Installer's Guide 3 1. INTRODUCTION PowerMaster-10 G2 and PowerMaster-30 G2 are PowerG-enabled pr

Página 24

5. PROGRAMMING 30 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.3.1 Identical Installer and Master Installer Codes In a 2-installer code syst

Página 25 - 4.11 Battery Insertion

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 31   - Adding New Devices [1] Enter "INSTALLER MODE", select "

Página 26 - Figure 4.13

5. PROGRAMMING 32 D-304762 PowerMaster-10/30 G2 Installer's Guide Step 9  Step 10  Step 11 Enter Device Settings Menu [9] Configure Device Par

Página 27 - 5. PROGRAMMING

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 33 No. Location Name No. Location Name No. Location Name No. Location Na

Página 28 - 5.2.2 Selecting options

5. PROGRAMMING 34 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.4.3 Deleting a Device Step 1  Step 2  Step 3  Step 4  Step 5 Select "

Página 29 - – Setting Installer Codes

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 35 To Replace, a device proceed as follows: Step 1  Step 2  Step 3  Step 4  St

Página 30 - 5.4 Zones / Devices

5. PROGRAMMING 36 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.4.7 Configuring Soak Test Mode1 This option enables you to enter device zones

Página 31 - Part B - Configuration

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 37 To enter the "03.CONTROL PANEL" menu and to select and configure an o

Página 32 - - Configuring New Devices

5. PROGRAMMING 38 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions CP-01 features not to be enabled in UL Liste

Página 33

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 39 Option Configuration Instructions premises and activating an "Entry Delay

Página 34 - 5.4.5 Replacing a Device

1. INTRODUCTION 4 D-304762 PowerMaster-10/30 G2 Installer's Guide Device Configuration Device parameters and related system behavior can be conf

Página 35 - – Changing Defaults

5. PROGRAMMING 40 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.5.4 Configuring Alarms & Troubles The following table provides you with

Página 36 - 5.5 Control Panel

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 41 Option Configuration Instructions 2. To comply with UL or CP-01 requirements,

Página 37 - 02:ENTRY DELAY2

5. PROGRAMMING 42 D-304762 PowerMaster-10/30 G2 Installer's Guide 45:STROBE TIME Define the length of time the strobe light will flash upon alarm

Página 38 - SMS REPORT

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 43 Option Configuration Instructions 56:SCREEN SAVER With Partition disabled The

Página 39 - 22:CROSS ZONING

5. PROGRAMMING 44 D-304762 PowerMaster-10/30 G2 Installer's Guide Notes: 1. To comply with EN requirements, 1 hour or 2 hours must be selected. 2

Página 40

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 45 Notes: 1. GPRS cannot be enabled in UL Listed product. 2. SMS is a supplementar

Página 41 - 44:SIREN TIME

5. PROGRAMMING 46 D-304762 PowerMaster-10/30 G2 Installer's Guide Step 1 Step 2 Step 3 Step 4 Select "COMMUNICATION" Select Commu

Página 42

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 47 5.6.3 Configuring GSM-GPRS (IP) - SMS Cellular Connection The GSM/GPRS module i

Página 43

5. PROGRAMMING 48 D-304762 PowerMaster-10/30 G2 Installer's Guide PowerMaster String Editor Key String Editor Functionality Moves the digits cur

Página 44 - 5.6 Communication

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 49 Option Configuration Instructions Enter the "1st RPRT CHAN"; option

Página 45

1. INTRODUCTION D-304762 PowerMaster-10/30 G2 Installer's Guide 5 Wired zones and programmable outputs (PGM) The control panel can support wired

Página 46

5. PROGRAMMING 50 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions Enter the two telephone numbers (including a

Página 47

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 51 Option Configuration Instructions Close"). The report enabled option send

Página 48 - PowerMaster String Editor

5. PROGRAMMING 52 D-304762 PowerMaster-10/30 G2 Installer's Guide The PowerMaster allows you also to select which event groups will be reported t

Página 49

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 53 Option Configuration Instructions →→→→3rd e-mail →→→→4th e-mail →→→→1st MMS te

Página 50

5. PROGRAMMING 54 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions To program: Press to enter the "PSTN U

Página 51 - Event Reporting Chart

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 55 Enter "7:BROADBAND", select the menu to configure (see guidance above

Página 52 - 2nd e-mail

5. PROGRAMMING 56 D-304762 PowerMaster-10/30 G2 Installer's Guide PGM: BY DELAY Determine to activate the PGM output during the Exit and Entry de

Página 53

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 57 5.8.2 Record Speech1 You can record short-duration speech messages for the hous

Página 54 - 5.6.8 Broadband

5. PROGRAMMING 58 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.9 Diagnostics 5.9.1 General Guidance – "Diagnostics" Flow-Chart &am

Página 55 - 5.7 PGM Output

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 59 Enter the "WL DEVICES" menu, select the type of test you wish to perf

Página 56 - 5.8 Custom Names

1. INTRODUCTION 6 D-304762 PowerMaster-10/30 G2 Installer's Guide System Architecture: Security Detectors and Transmitters Main Control Pane

Página 57 - 5.8.3 Voice Box Mode

5. PROGRAMMING 60 D-304762 PowerMaster-10/30 G2 Installer's Guide Enter the "GSM/GPRS" menu, and press to initiate the GSM diagnostic t

Página 58

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 61 Message Description Cable unplugged The Ethernet cable is not connected to t

Página 59

5. PROGRAMMING 62 D-304762 PowerMaster-10/30 G2 Installer's Guide PYTHON:  GSM image transfer software version

Página 60 - 5.9.4 Testing the SIM Number

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 63 5.15.2 Select setting To select the desired operation mode, proceed as follows

Página 61 - 5.12 Serial Number

5. PROGRAMMING 64 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 06:CONFIRM PANIC A confirmed panic alarm i

Página 62 - 5.15 Operation Mode

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 65 Option Configuration Instructions 03:END EXIT MODE Define how the exit delay i

Página 63 - 5.15.3 BS8243 Setup

5. PROGRAMMING 66 D-304762 PowerMaster-10/30 G2 Installer's Guide 5.15.5 CP01 Setup 13:OPERATION MOD ⋅ ⋅ ⋅ CP01 SETUP Enter the "04:C

Página 64 - 5.15.4 DD243 Setup

5. PROGRAMMING D-304762 PowerMaster-10/30 G2 Installer's Guide 67 Option Configuration Instructions enable (default) and disable 13:ABORT ANOUN

Página 65

6. PERIODIC TEST 68 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions "cancel alarm" time, a “cancel a

Página 66 - 5.15.5 CP01 Setup

6. PERIODIC TEST D-304762 PowerMaster-10/30 G2 Installer's Guide 69 Option Instructions CONTINUE". During this time, the siren of the teste

Página 67 - 5.15.6 OTHERS Setup

2. CHOOSING THE INSTALLATION LOCATION D-304762 PowerMaster-10/30 G2 Installer's Guide 7 2. CHOOSING THE INSTALLATION LOCATION To ensure the best

Página 68 - 6. PERIODIC TEST

7. MAINTENANCE 70 D-304762 PowerMaster-10/30 G2 Installer's Guide Option Instructions "MOTION SENSORS". 2. Press ; the following sc

Página 69

7. MAINTENANCE D-304762 PowerMaster-10/30 G2 Installer's Guide 71 Fault What it means Solution AC SUPPLY FAILURE There is no power and the syst

Página 70 - 7. MAINTENANCE

7. MAINTENANCE 72 D-304762 PowerMaster-10/30 G2 Installer's Guide Fault What it means Solution 4. Enroll the device again. RSSI LOW The GSM co

Página 71

8. READING THE EVENT LOG D-304762 PowerMaster-10/30 G2 Installer's Guide 73 8. READING THE EVENT LOG Up to 100 events are stored in the event log

Página 72 - 7.6 Annual System Check

APPENDIX A. Specifications 74 D-304762 PowerMaster-10/30 G2 Installer's Guide APPENDIX A. Specifications A1. Functional PowerMaster-10 G2 Powe

Página 73 - 8. READING THE EVENT LOG

APPENDIX A. Specifications D-304762 PowerMaster-10/30 G2 Installer's Guide 75 PowerMaster-10 G2 PowerMaster-30 G2 Real Time Clock (RTC) The co

Página 74 - APPENDIX A. Specifications

APPENDIX A. Specifications 76 D-304762 PowerMaster-10/30 G2 Installer's Guide PowerMaster-10 G2 PowerMaster-30 G2 (2) 7.2V 1300 mAh, recharge

Página 75 - A3. Electrical

APPENDIX B. Working with Partitions D-304762 PowerMaster-10/30 G2 Installer's Guide 77 A5. Physical Properties PowerMaster-10 G2 PowerMaster-3

Página 76 - A4. Communication

APPENDIX B. Working with Partitions 78 D-304762 PowerMaster-10/30 G2 Installer's Guide Note: When Partition Mode is disabled, all zones, user cod

Página 77 - A5. Physical Properties

APPENDIX C. Detector Deployment & Transmitter Assignments D-304762 PowerMaster-10/30 G2 Installer's Guide 79 APPENDIX C. Detector Deployment

Página 78 - B2. Common Areas

3. POWERMASTER-10 G2 INSTALLATION 8 D-304762 PowerMaster-10/30 G2 Installer's Guide 3. POWERMASTER-10 G2 INSTALLATION Required tool: Philips scre

Página 79 - Assignments

APPENDIX C. Detector Deployment & Transmitter Assignments 80 D-304762 PowerMaster-10/30 G2 Installer's Guide Zone Zone Type Location Chime (m

Página 80 - C2. Keyfob Transmitter List

APPENDIX C. Detector Deployment & Transmitter Assignments D-304762 PowerMaster-10/30 G2 Installer's Guide 81 C4. Non-Alarm Transmitter List T

Página 81

APPENDIX D. Event Codes 82 D-304762 PowerMaster-10/30 G2 Installer's Guide APPENDIX D. Event Codes D1. Contact ID Event Codes Code Definition C

Página 82 - APPENDIX D. Event Codes

APPENDIX D. Event Codes D-304762 PowerMaster-10/30 G2 Installer's Guide 83 Code Definition Code Definition FT Fire Detector Clean XT Sensor B

Página 83 - Type Number Range

APPENDIX E. Sabbath Mode 84 D-304762 PowerMaster-10/30 G2 Installer's Guide APPENDIX E. Sabbath Mode E1. General Guidance The Sabbath Mode allows

Página 84 - APPENDIX E. Sabbath Mode

APPENDIX F. PowerLink3 IP Communicator, D-304762 PowerMaster-10/30 G2 Installer's Guide 85 APPENDIX F. PowerLink3 IP Communicator1, 2 IMPORTANT N

Página 85 - F2. Specifications

APPENDIX F. PowerLink3 IP Communicator, 86 D-304762 PowerMaster-10/30 G2 Installer's Guide F3. Installation Package Contents 1 x Visonic PowerLin

Página 86 - F3. Installation

APPENDIX F. PowerLink3 IP Communicator, D-304762 PowerMaster-10/30 G2 Installer's Guide 87 Hardware Installation Step 1. Open the control panel:

Página 87 - Hardware Installation

APPENDIX F. PowerLink3 IP Communicator, 88 D-304762 PowerMaster-10/30 G2 Installer's Guide Step 3 PowerMaster-10 G2: 1. Connect the flat cable f

Página 88

APPENDIX F. PowerLink3 IP Communicator, D-304762 PowerMaster-10/30 G2 Installer's Guide 89 Step 4. Close the panel and secure with 2 screws: Pow

Página 89 - Control Panel Configuration

3. POWERMASTER-10 G2 INSTALLATION D-304762 PowerMaster-10/30 G2 Installer's Guide 9 3.2 Connecting to the Telephone Line PHONE WIRING Connect the

Página 90 - APPENDIX G. Glossary

APPENDIX G. Glossary 90 D-304762 PowerMaster-10/30 G2 Installer's Guide APPENDIX G. Glossary Abort Period: When an alarm is initiated, the intern

Página 91

APPENDIX G. Glossary D-304762 PowerMaster-10/30 G2 Installer's Guide 91 Location: Assigning a named location to a device (for example, Garage, Fr

Página 92 - Standards

APPENDIX H. Compliance with Standards 92 D-304762 PowerMaster-10/30 G2 Installer's Guide APPENDIX H. Compliance with Standards Compliance with St

Página 93 - WARRANTY

D-304762 PowerMaster-10/30 G2 Installer's Guide 93 WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "P

Página 94

94 D-304762 PowerMaster-10/30 G2 Installer's Guide

Página 95 - Preparing to Arm

PowerMaster-10/30 G2 Quick User Guide PowerMaster-10/30 G2 Quick User Guide Arming and Disarming the System Step Operation User Actions Notes Optiona

Página 96 - Zone Bypass Scheme

PowerMaster-10/30 G2 Quick User Guide To review the open zones click . The details and location of the first open zone detector (usually an open door

Comentários a estes Manuais

Sem comentários