www.visonic.comPowerMaster-10 G2INSTALLER GUIDEFully supervised wireless alarm control system
3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 9 3.2 Connecting to the Telephone Line PHONE WIRING Connect th
3. POWERMASTER-10 G2 INSTALLATION 10 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.3 System Planning & Programming Program the system no
3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 11 3.5 PGM-5 Installation PGM-5 is an output interface module
3. POWERMASTER-10 G2 INSTALLATION 12 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.6 Adding Wired Zones or PGM Device Required tools: Cutter
3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 13 PGM AND ZONE WIRING A. PGM output Vmax=30v Imax=100mA B
3. POWERMASTER-10 G2 INSTALLATION 14 D-303222 PowerMaster-10/30 G2 Installer's Guide Notes for UL installations: 1. A device that is connected
3. POWERMASTER-10 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 15 CONNECTING AC POWER USING INTERNAL AC/DC POWER SUPPLY UNIT
3. POWERMASTER-10 G2 INSTALLATION 16 D-303222 PowerMaster-10/30 G2 Installer's Guide 3.8 Supplying Power to the Unit Connect power to the Power
4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 17 4. POWERMASTER-30 G2 INSTALLATION Required tool: Philips s
4. POWERMASTER-30 G2 INSTALLATION 18 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.2 Opening the PowerMaster-30 G2 Control Panel and Bracke
D-303222 PowerMaster-10/30 G2 Installer's Guide 1 PowerMaster-10/30 G2 Version 16 Installer's Guide Table of Contents 1. INTRODUCTION ...
4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 19 PHONE WIRING IN NORTH AMERICA A. LINE B. SET C. RJ-31X
4. POWERMASTER-30 G2 INSTALLATION 20 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.6 GSM Module Installation (detail "N" in Figur
4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 21 1. To install the DUAL RS-232 module into the control pane
4. POWERMASTER-30 G2 INSTALLATION 22 D-303222 PowerMaster-10/30 G2 Installer's Guide A. PowerMaster-30 G2 connector B. Front unit C. PGM-5
4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 23 OPTIONAL EXPANDER MODULE, ZONES, SIRENS, AUDIO BOX AND WIRE
4. POWERMASTER-30 G2 INSTALLATION 24 D-303222 PowerMaster-10/30 G2 Installer's Guide The 12V and "GND" terminals can be connected to a
4. POWERMASTER-30 G2 INSTALLATION D-303222 PowerMaster-10/30 G2 Installer's Guide 25 EXTERNAL POWER CONNECTION Connect the power adaptor to the
4. POWERMASTER-30 G2 INSTALLATION 26 D-303222 PowerMaster-10/30 G2 Installer's Guide 4.13 Closing the PowerMaster-30 G2 Control Panel Control p
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 27 5. PROGRAMMING 5.1 General Guidance This chapter explains the Installer progra
5. PROGRAMMING 28 D-303222 PowerMaster-10/30 G2 Installer's Guide To enter the "Installer Mode" and select an Installer Menu Option pr
2 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.6.1 General Guidance – "Communication" Flow-Chart & Menu Options ...
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 29 [3] The system exits the “INSTALLER MODE" menu and returns to the normal
5. PROGRAMMING 30 D-303222 PowerMaster-10/30 G2 Installer's Guide (b) i) Change the Installer Code to a temporary code, ii) exit the Instal
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 31 [3] The display shows the device details and the first available free Zone num
5. PROGRAMMING 32 D-303222 PowerMaster-10/30 G2 Installer's Guide - Configuring New Devices Location (name) setting: [1] To review
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 33 Zone Type List No. Zone Type Description 1. Exit/Entry 1 This Zone starts th
5. PROGRAMMING 34 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.4.3 Deleting a Device Step 1 Step 2 Step 3 Step 4 Step 5 Select &quo
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 35 To Replace, a device proceed as follows: Step 1 Step 2 Step 3 Step 4 S
5. PROGRAMMING 36 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.4.7 Updating Devices after Exiting Installer Mode When exiting the "In
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 37 5.5.8 91:USER PERMIT 92:BATTERY TYPE 5.5.2 Configuring Ar
5. PROGRAMMING 38 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 07:LATCHKEY ARM When "ON", a “la
1. INTRODUCTION D-303222 PowerMaster-10/30 G2 Installer's Guide 3 1. INTRODUCTION PowerMaster-10 G2 and PowerMaster-30 G2 are PowerG-enabled p
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 39 Option Configuration Instructions 3. CP-01 was tested and certified by ETL/Int
5. PROGRAMMING 40 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions disarms the system within the delay time, th
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 41 45:STROBE TIME Define the length of time the strobe light will flash upon alar
5. PROGRAMMING 42 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 56:SCREEN SAVER With Partition disabled The
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 43 "SUPERVISION" Options: after 1/2/4/8/12 (default) hour(s); and disab
5. PROGRAMMING 44 D-303222 PowerMaster-10/30 G2 Installer's Guide 5:MOTION CAMERA Contains configurable features and parameters related to Motio
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 45 5.6.2 Configuring PSTN (landline phone) Connection The PowerMaster panels incl
5. PROGRAMMING 46 D-303222 PowerMaster-10/30 G2 Installer's Guide SIM PIN CODE Enter the PIN code of the SIM card installed in the GSM module
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 47 5.6.4 Configuring Events Reporting to Monitoring Stations The PowerMaster con
5. PROGRAMMING 48 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions Entering Hexadecimal Digits Digit 0…..9 A
1. INTRODUCTION 4 D-303222 PowerMaster-10/30 G2 Installer's Guide Device Configuration Device parameters and related system behavior can be conf
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 49 Option Configuration Instructions Note: For UL installations, the communicatio
5. PROGRAMMING 50 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions Voice <- -> C.S. Ringback time Ambi
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 51 5.6.5 Configuring Events Reporting to Private Users The PowerMaster system can
5. PROGRAMMING 52 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions VIEW TIME WINDOW “VIEW TIME WINDOW” menu app
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 53 Option Configuration Instructions UL/DL modes Define whether the downloading
5. PROGRAMMING 54 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.7.5 PGM Output Configuration Option Configuration Instructions PGM: BY
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 55 Option Configuration Instructions CUST. ZONES NAME TEXT LOC. #05 1 TEXT
5. PROGRAMMING 56 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.8.3 Voice Box Mode1 This mode allows you to determine whether two-way
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 57 Option Instructions TEST ALL DEVICES You can test all devices automatically, o
5. PROGRAMMING 58 D-303222 PowerMaster-10/30 G2 Installer's Guide The following table presents the test result messages Message Description Unit
1. INTRODUCTION D-303222 PowerMaster-10/30 G2 Installer's Guide 5 Wired zones and programmable outputs (PGM) The control panel can support wired
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 59 5.13 Start UL/DL Note: This option is only used during the installation of pa
5. PROGRAMMING 60 D-303222 PowerMaster-10/30 G2 Installer's Guide 5.15.2 Select between EN-50131, DD243 and BS8243 To select the desired operati
5. PROGRAMMING D-303222 PowerMaster-10/30 G2 Installer's Guide 61 Option Configuration Instructions 06:CONFIRM PANIC A confirmed panic alarm i
6. PERIODIC TEST 62 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Configuration Instructions 04:FOB/KP PANIC Define the devices that
6. PERIODIC TEST D-303222 PowerMaster-10/30 G2 Installer's Guide 63 6.2 Conducting a Periodic Test The PowerMaster enables you to conduct the p
6. PERIODIC TEST 64 D-303222 PowerMaster-10/30 G2 Installer's Guide Option Instructions 1. Press to view details of the next untested device.
7. MAINTENANCE D-303222 PowerMaster-10/30 G2 Installer's Guide 65 Option Instructions 3. Press continuously to navigate to a different zone
7. MAINTENANCE 66 D-303222 PowerMaster-10/30 G2 Installer's Guide Fault What it means Solution JAMMING A radio-frequency signal which is blockin
8. READING THE EVENT LOG D-303222 PowerMaster-10/30 G2 Installer's Guide 67 7.6 Annual System Check Note: The PowerMaster system must be checked
APPENDIX A. Specifications 68 D-303222 PowerMaster-10/30 G2 Installer's Guide APPENDIX A. Specifications A1. Functional PowerMaster-10 G2 Power
1. INTRODUCTION 6 D-303222 PowerMaster-10/30 G2 Installer's Guide System Architecture: Security Detectors and Transmitters Main Control Pan
APPENDIX A. Specifications D-303222 PowerMaster-10/30 G2 Installer's Guide 69 PowerMaster-10 G2 PowerMaster-30 G2 Real Time Clock (RTC) The con
APPENDIX A. Specifications 70 D-303222 PowerMaster-10/30 G2 Installer's Guide PowerMaster-10 G2 PowerMaster-30 G2 by GP or equivalent. 4. 9.6V
APPENDIX B. Working with Partitions D-303222 PowerMaster-10/30 G2 Installer's Guide 71 Range Humidity 93% relative humidity, @ 30°C (86°F) 93% r
APPENDIX C. Detector Deployment & Transmitter Assignments 72 D-303222 PowerMaster-10/30 G2 Installer's Guide B2. Common Areas Common areas a
APPENDIX C. Detector Deployment & Transmitter Assignments D-303222 PowerMaster-10/30 G2 Installer's Guide 73 Zone Zone Type Location Chime (
APPENDIX D. Event Codes 74 D-303222 PowerMaster-10/30 G2 Installer's Guide C2. Keyfob Transmitter List Transmitter Data AUX button Assignments N
APPENDIX D. Event Codes D-303222 PowerMaster-10/30 G2 Installer's Guide 75 120 Panic 373 Fire detector trouble 121 Duress 380 Sensor trouble 1
APPENDIX E. Sabbath Mode 76 D-303222 PowerMaster-10/30 G2 Installer's Guide D3. Understanding the Scancom Reporting Protocol Data Format The SCA
APPENDIX F. Glossary D-303222 PowerMaster-10/30 G2 Installer's Guide 77 Wiring Setup A. MC-302E device B. Wired magnetic contact C. Fixed frame
APPENDIX F. Glossary 78 D-303222 PowerMaster-10/30 G2 Installer's Guide Disarming: The opposite of arming - an action that restores the control
2. CHOOSING THE INSTALLATION LOCATION D-303222 PowerMaster-10/30 G2 Installer's Guide 7 2. CHOOSING THE INSTALLATION LOCATION To ensure the best
APPENDIX G. Compliance with Standards D-303222 PowerMaster-10/30 G2 Installer's Guide 79 APPENDIX G. Compliance with Standards Compliance with S
APPENDIX G. Compliance with Standards 80 D-303222 PowerMaster-10/30 G2 Installer's Guide WARRANTY Visonic Limited (the “Manufacturer") wa
© 2013 Visonic Ltd. All rights reserved. PowerMaster-10 / PowerMaster-30 English Installer Guide D-303222www.visonic.comFully supervised wireless alar
3. POWERMASTER-10 G2 INSTALLATION 8 D-303222 PowerMaster-10/30 G2 Installer's Guide 3. POWERMASTER-10 G2 INSTALLATION Required tool: Philips scr
Comentários a estes Manuais