N/A = No Information Available
DMP XR150D/XR150N
The DMP XR150 and XR150N Panels provide dealers and end-users with an integrated feature package. With an extensive feature set this panel the obvious choice for all your burglary, re, and access control applications. The XR150 Series provides 10
on-board zones, up to 142 programmable zones, 106 programmable outputs, 102 programmable Form C relays, and 10,000 User Codes with 99 separate proles. The XR150N offers on-board network support. Program common areas, cross-zoned areas,
primary and secondary schedules, temporary and permanent schedules, output schedules, and view a history of up to 12,000 events. Compatible with the complete line of DMP 1100X Series Two-Way Wireless, providing support for up to 100 DMP Wireless
devices.
Compares to:
Bosh 7271GV4
Gemini X255
MAXSYS PC4020
NetworkX NX-8
Vista 128BPT
DMP XR150D DMP XR150N Bosch 7212GV4 Gemini P9600 MAXSYS PC4020 NetworkX NX-8 Vista 128BPT
Zone Information
Maximum Zones
142 142 40 96 128 48 128
Control Panel Zones
10 10 8 8 16 8 9
Control Panel Fire Zones
2 2 8 unpowered, needs module for
powered two wire smoke detectors
up to 8 two wire re zones N/A N/A 1
Hardwired Expansion Zones
132 132 32 88 N/A 48 119
Wireless Expansion Zones
DMP 1100 Series (100 Zones) DMP 1100 Series (100 Zones) 32 using Inovonics product 96 using GEM-RECV96 receiver N/A 48 127
Zone Expansion Bus(es)
Keypad (64 Zones) 1 on-board
LX-Bus (100 Zones per bus) up
to 15,000 foot bus using 710 bus
splitter repeater module and
remote power supplies. No more
than a 2 Vdc drop over entire data
bus at this distance. Use standard
18 AWG 4 conductor non-shielded
non-twisted wire.
Keypad (64 Zones) 1 on-board
LX-Bus (100 Zones per bus) up
to 15,000 foot bus using 710 bus
splitter repeater module and
remote power supplies. No more
than a 2 Vdc drop over entire data
bus at this distance. Use standard
18 AWG 4 conductor non-shielded
non-twisted wire.
32 on zonex bus 88 N/A 40 119
Zone expander modules
711/712-8/714/714-8/714-16/715/
715-8/715-16/716
711/712-8/714/714-8/714-16/715/
715-8/715-16/716
Uses Zonex and DS Mux Devices GEM-EZM8 N/A N/A Must use V-Plex Devices
Powered Smoke Zones
2 onboard, expandable to 102 2 onboard, expandable to 102 N/A N/A N/A N/A N/A
Maximum 2-Wire Smoke Detectors
12 (521B)/ 10 (2W-B, 2WT-B) per
zone, Maximum 130 zones
12 (521B)/ 10 (2W-B, 2WT-B) per
zone, Maximum 130 zones
N/A N/A N/A N/A N/A
Keypad/Access Information
Max Supervised Keypads
8 8 8 N/A 16 N/A 6
Max Unsupervised Keypads
Unlimited Unlimited 32 N/A N/A N/A N/A
Doors of Access
8 8 N/A N/A N/A N/A 8 doors using V-Plex addressable
VistaKey Access Control up to 250
cards.
Wiegand Input Keypads
Yes Yes N/A N/A N/A N/A N/A
Fully Keypad Programmable
Yes Yes Yes N/A N/A N/A N/A
Keypad Compatible with all products
Yes Yes No N/A N/A N/A N/A
Power & Output information
Auxiliary Power
1.5A 1.5A 1.4A 750 mA combined aux power and
reset relay power
N/A 1 Amp 750mA
Bell Power
1.5A 1.5A 2A N/A N/A Shared with Aux Power 1.7Amps
Maximum Ah of Batteries supported by
Control Panel
67 Amp hours of batteries
supported
67 Amp hours of batteries
supported
38Ah N/A N/A N/A 4 or 7 Ah battery
Auxiliary Output
2 Form “C” 4 Open Collector
outputs onboard expandable to 100
outputs offboard
2 Form “C” 4 Open Collector
outputs onboard expandable to 100
outputs offboard
27 3 on board expandable to 96 N/A N/A 96
DMP Product Comparisons Guide Digital Monitoring Products