N/A = No Information Available
DMP XR100/XR100N Bosch D7412GV3 Ademco Vista-128FBP FBII XL-5 GE Interlogix Concord
Ultra
GE Interlogix Advent
(60-525-03)
DSC MAXSYS PC4020 ITI Concord 60-734-01
60-746-01
False Alarm Reduction Features
Cancel/Verify
Yes No No No No No No No
Exit Error
Yes No Ye s Ye s Ye s No Ye s Ye s
Fire Verify Zones
Yes Yes Yes Yes Yes No No Ye s
Cross Zoning
Yes No Ye s Ye s Ye s No Ye s Ye s
Abort Reporting
Yes Yes No Ye s Ye s Ye s Ye s Ye s
System Test by User
Yes Yes Yes No No No No Ye s
System Recently Armed
Yes No Ye s No Ye s No Ye s Ye s
Programmable Entry/Exit Delays
Yes Yes Yes 2 entry delays Yes Yes No Ye s
Transmit Delay
Yes Yes No No Ye s Ye s Ye s Ye s
Swinger Zone Bypassing
Yes Yes No No Ye s Ye s Ye s Ye s
Report Bypass to Central Station
Yes Yes No No Ye s Ye s No Ye s
Unique Duress Code
Yes Yes No Ambush code capability Yes No No Ye s
Call Waiting Cancel
Yes No Ye s No Ye s No No Ye s
Multi-linguial Menus Available
English/Spanish/French No No No No No No No
Compliance
FDNY New York City
Yes Yes Yes No No No No No
California State Fire Marshal (CSFM)
Yes Yes Yes No Ye s Ye s Ye s Ye s
ANSI/UL 294 Access Control System Units
Yes No No No No No No No
ANSI/UL 365 Police Connected Burglar
Yes Yes Yes No No Ye s Ye s Ye s
ANSI/UL 609 Local Burglar
Yes Yes Yes No No Ye s Ye s Ye s
ANSI/UL 864 Fire Protective Signaling
Systems
Yes Yes Yes No No No Ye s No
ANSI/UL 985 Household Fire Warning
Yes Yes Yes No Ye s Ye s Ye s No
ANSI/UL 1023 Household Burglar
Yes Yes Yes No Ye s Ye s Ye s Ye s
ANSI/UL 1076 Proprietary Burglar
Yes No No No No No No No
ANSI/UL 1610 Central Station Burglar
Yes Yes Yes No No Ye s Ye s Ye s
ANSI/UL 1635 Digital Burglar
Yes Yes No No Ye s Ye s Ye s No
SIA-CP-01-2010 False Alarm Reduction
Yes No Yes requires Vista-128 PSIA No Ye s No No No
ULC-S304 Standard for Central and
Monitoring Station Burglar Alarm Units.
Yes N/A N/A N/A N/A N/A N/A N/A
ULC-S545 Standard for Residential Fire
Warning System Control Units
Yes N/A N/A N/A N/A N/A N/A N/A
ULC-S559 Fire Signal Receiving Centres
Systems
Yes N/A N/A N/A N/A N/A N/A N/A
ULC Subject-C1023 Household Burglar Alarm
System Units
Yes N/A N/A N/A N/A N/A N/A N/A
ULC/ORD-C1076 Standard for Proprietary
Burglar Alarm Units and Systems
Yes N/A N/A N/A N/A N/A N/A N/A
Made in U.S.A.
Yes No No No No No No No
DMP XR100 and XR100N (continued)
DMP Product Comparisons Guide Digital Monitoring Products
9
COMPARISONS NOte