D-302990 1 PowerMaxExpress User Guide Table of Contents Quick Guide to Primary Alarm Control Operations...
SECURING THE PROTECTED SITE 10 D-302990 Initiating a Panic Alarm You can generate a panic alarm manually in the disarmed and armed states alike. The
SPEECH AND SOUND CONTROL D-302990 11 ARM indicator extinguishes and sounds once per minute, To find out what kind of trouble is being sensed, see
READING ALARM MEMORY AND TROUBLE DATA 12 D-302990 3. Reading Alarm Memory and Trouble Data Reviewing Alarm/Tamper Memory The PowerMaxExpress retains
READING ALARM MEMORY AND TROUBLE DATA D-302990 13 • CPU low battery - The backup battery within the control panel is weak and must be replaced (see
SPECIAL FUNCTIONS 14 D-302990 4. Special Functions Looking after People Left at Home An important characteristic of the PowerMaxExpress is its abilit
SPECIAL FUNCTIONS D-302990 15 B. Executable Commands Command Keying Sequence Disarming [][1][#] Arming Home [][2][#] Arming Home-Instant []
SPECIAL FUNCTIONS 16 D-302990 Note: Status messages can be sent only to a calling telephone whose identity number is not blocked by the user! Note: T
USER SETTINGS D-302990 17 5. User Settings What are the Settings You Need? The installer provides you with a ready-to-use alarm system, but a few set
USER SETTINGS 18 D-302990 Bypassing Zones A. General Guidance You can program the PowerMaxExpress to exclude (bypass) selected zones, regardless of w
USER SETTINGS D-302990 19 Recalling the Last Bypass Scheme Arming the alarm system with several zones in the bypassed state is in fact "partial
2 D-302990 Quick Guide to Primary Alarm Control Operations QUICK REFERENCE TO PRIMARY ALARM CONTROL OPERATIONS Arming AWAY ...
USER SETTINGS 20 D-302990 Enrolling Keyfob Transmitters Eight system users carry keyfob transmitters to exercise better, quicker and safer system fun
USER SETTINGS D-302990 21 PRIVATE REPORTRECALL BYPASSSET BYPASSREADY 00:00(5)(5)<OK> TO RECALLWALK TEST<OK> TO BYPASS Z01: BYPASSEDZ01: O
USER SETTINGS 22 D-302990 Notes: (1) Functions inside black rectangles are accessible only if master user code was entered. (2) For the year, enter
USER SETTINGS D-302990 23 Enabling the Squawk Option You can determine that the system will activate (or not activate) high/mid/low wireless siren so
USER SETTINGS 24 D-302990 Scheduler Function The Scheduler enables to start and stop activity of the desired devices. You can select the day (Sunday,
READING THE EVENT LOG D-302990 25 6. Reading The Event Log Event Log Description All events are memorized in an event log that contains up to 100 ent
MAINTENANCE 26 D-302990 7. Maintenance Replacing the Backup Battery The PowerMaster-10 uses regular electrical supply, but incorporates rechargeable
PERFORMANCE LIMITS D-302990 27 8. Performance Limits Although the alarm control system you purchased is highly reliable, it does not guarantee protec
APPENDICES 28 D-302990 APPENDIX A. GLOSSARY This list of terms is arranged in alphabetical order. Any term indicated by cursive (italic) letters with
APPENDICES D-302990 29 Latchkey: The Latchkey mode is a special arming mode in which designated "latchkey users" will trigger a "latc
D-302990 3 Siren Signals Alarm Type Graphic Representation of Signal Verbal Description of Signal Burglar / 24 hour/ Panic –––––––––––––––––––––––
APPENDICES 30 D-302990 APPENDIX B. HOME FIRE ESCAPE PLANNING Fire can spread rapidly through your home, leaving you a short time to escape safely. Yo
D-302990 31 WARNING! Owner's instruction notice: "Not to be removed by anyone except occupant". If the “PowerMax Express” causes harm
32 D-302990 W.E.E.E. Product Recycling Declaration For information regarding the recycling of this p
INTRODUCTION 4 D-302990 1. Introduction OverviewThe PowerMaxExpress is a wireless alarm control system that provides protection against burglary, fi
INTRODUCTION D-302990 5 KEYFOBTRANSMITTERUP TO 8WIRELESSREMOTECOMMANDERSEMERGENCYPENDANTTRANSMITTERSWIRELESSDETECTORS(UP TO 28 UNITS)INSTALLED INTHE
INTRODUCTION 6 D-302990 Terms of the Trade Better understanding of your system is assured if you take time to read the definitions in APPENDIX B at
INTRODUCTION D-302990 7 MKP-150 /151 AWAY Figure 4. Keyfob Transmitters and Keypad A PANIC alarm can be initiated: through the MCT-234 keyfob, by pr
SECURING THE PROTECTED SITE 8 D-302990 2. Securing the Protected Site Security-Related Pushbuttons Key Function Arming when nobody is at home Arming
SPEECH AND SOUND CONTROL D-302990 9 If you wish to arm AWAY-INSTANT, proceed as follows. PRESS RESULTANT DISPLAY ENTER CODE _ _ _ _ ARMING AWAY
Comentários a estes Manuais