DE5450P PowerMax Programming Guide 1
POWERMAX
POWERMAXPOWERMAX
POWERMAX
Fully Supervised Wireless Alarm Control System
Programming Guide
TABLE OF CONTENTS
TABLE OF CONTENTSTABLE OF CONTENTS
TABLE OF CONTENTS
1. INTRODUCTION ............................................................. 2
1.1 General Guidance.................................................. 2
1.2 Accessing the Installer’s Menu .............................. 2
2. SETTING A NEW INSTALLER CODE .......................... 3
3. ENROLLING WIRELESS DEVICES AND KEYFOBs .. 3
3.1 General Guidance.................................................. 3
3.2 Wireless Devices ................................................... 3
3.3 Keyfob Transmitters ............................................... 3
3.4 Deleting Device and Keyfob IDs ............................ 4
4. DEFINING ZONE TYPES .............................................. 5
4.1 Preliminary Guidance ............................................ 5
4.2 Zone Definition Procedure ..................................... 5
5. DEFINING CONTROL PANEL PARAMETERS ........... 7
5.1 Preliminary Guidance ............................................ 7
5.2 Entry Delays........................................................... 7
5.3 Exit Delay ............................................................... 7
5.4 Bell Time ................................................................ 7
5.5 Abort Time ............................................................. 7
5.6 Alarm Cancel Time ................................................ 7
5.7 Quick Arming ......................................................... 9
5.8 Bypass ................................................................... 9
5.9 Restart Exit ............................................................ 9
5.10 Piezo Beeps ......................................................... 9
5.11 Trouble Beeps ..................................................... 9
5.12 Panic Alarm ......................................................... 9
5.13 Swinger Stop ....................................................... 9
5.14 Cross Zoning ....................................................... 9
5.15 Supervision Interval ............................................. 9
5.16 AUX Button ........................................................ 10
5.17 Jamming Detection ............................................ 10
5.18 Two-Way Voice - Private Telephones ............... 10
5.19 Two-Way Voice - Central Stations .................... 10
5.20 PGM / X-10 Time ............................................... 10
5.21 Lighting Lockout Time ....................................... 10
5.22 Latchkey Arming ................................................ 10
5.23 “Not Active” Time ............................................... 10
5.24 Back Lighting ..................................................... 10
5.25 Duress Alarm (ambush) .................................... 11
5.26 Piezo Siren ........................................................ 11
6. DEFINING COMMUNICATION PARAMETERS ......... 11
6.1 Preliminary Guidance .......................................... 11
6.2 Dialing Method..................................................... 12
6.3 Phone Line Test Interval ..................................... 12
6.4 First Central Station Telephone .......................... 12
6.5 First Account No. ................................................. 12
6.6 Second Central Station Telephone ..................... 12
6.7 Second Account No. ............................................ 12
6.8 Report Format ..................................................... 12
6.9 4/2 Pulse Rate ..................................................... 12
6.10 Reporting to Central Stations ............................ 12
6.11 Dialing Attempts ................................................ 14
6.12 First Private Telephone No. .............................. 14
6.13 Second Private Telephone No. ......................... 14
6.14 Third Private Telephone No. ............................. 14
6.15 Telephone Message Type ................................. 14
6.16 Private Tel. Dialing Attempts ............................. 14
6.17 Reporting to Private Telephones....................... 14
6.18 Telephone Acknowledge ................................... 14
6.19 Pager Telephone Number ................................. 14
6.20 Pager’s PIN No. ................................................. 14
6.21 Reporting to a Pager ......................................... 14
6.22 Recent Closure .................................................. 15
6.23 Remote Access ................................................. 15
6.24 Downloader Code .............................................. 15
7. DEFINING OUTPUT PARAMETERS ......................... 15
7.1 Preliminary Guidance .......................................... 15
7.2 PGM Output Control ............................................ 16
7.3 Controlling the X-10 Units ................................... 16
8. RECORDING SPEECH ............................................... 17
8.1 Mode Description and Activation ......................... 17
8.2 Recording Procedure .......................................... 17
9. DIAGNOSTIC TEST .................................................... 17
9.1 Mode Description and Activation ......................... 17
9.2 Test Procedure .................................................... 18
10. USER FUNCTIONS .................................................... 18
11. READING THE EVENT LOG ..................................... 18
11.1 Event Log Description ....................................... 18
11.2 Reading Procedure ........................................... 18
11.3 Erasing the Event Log ....................................... 19
APPENDIX A. EVENT CODES ........................................ 20
APPENDIX B. PROGRAMMABLE ZONE TYPES ........... 22
WARNING! The PowerMax control unit has not been investigated by UL for household fire.
WARNING! All model PowerMax outputs are not power limited and shall not be used in UL-listed Systems.
WARNING! Zone type "emergency" can not be used for medical applications in UL-listed systems.
If you re-program a system already in use, the previous system status will be erased upon quitting the installer menu.
Be sure to conduct a full walk test, including all windows and doors, to allow re-capture of the system status.
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - Programming Guide

DE5450P PowerMax Programming Guide 1 POWERMAXPOWERMAXPOWERMAXPOWERMAX Fully Supervised Wireless Alarm Control System Programming Guide TABLE OF

Página 2 - 1. INTRODUCTION

10 DE5450P PowerMax Programming Guide 5.16 AUX Button Here you select the function of the AUX button on keyfob transmitters. Three options are off

Página 3 - 3.3 Keyfob Transmitters

DE5450P PowerMax Programming Guide 11 Upon selecting Location 24, the display will change to: 2 4 : B A C K L I G H T Select the desired option

Página 4

12 DE5450P PowerMax Programming Guide With the correct number on display and the blinking cursor to the right of the last digit, click <OK

Página 5 - 4. DEFINING ZONE TYPES

DE5450P PowerMax Programming Guide 13 Plan name Sent to center 1 Sent to center 2 all γγγγ backup All events all –o/c γγγγ backup All but open/cl

Página 6

14 DE5450P PowerMax Programming Guide 6.11 Dialing Attempts Here you determine how many times the communicator will dial the central station’

Página 7 - C. Programming Method

DE5450P PowerMax Programming Guide 15 6.22 Recent Closure Here you enable or disable the “recent closing” report, that is sent to the centra

Página 8

16 DE5450P PowerMax Programming Guide B. Gaining Access to the “Define Outputs” Mode  Upon gaining access to the installer menu (see Section 1),

Página 9

DE5450P PowerMax Programming Guide 17 • Select the factors that will activate each X-10 unit. The list of factors is the same as for the PGM

Página 10

18 DE5450P PowerMax Programming Guide A. Upon gaining access to the installer menu (see Section 1), the display will read “1. NEW INSTL CODE”. B. Cli

Página 11 - A. Mode description

DE5450P PowerMax Programming Guide 19 Important! Entering an incorrect code 5 times in a row will initiate a 30-second penalty lockout of the keypad

Página 12

2 DE5450P PowerMax Programming Guide 1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION1. INTRODUCTION 1.1 General Guidance We recommend to program

Página 13 - C N T R

20 DE5450P PowerMax Programming Guide APPENDIX A. EVENT CODESAPPENDIX A. EVENT CODESAPPENDIX A. EVENT CODESAPPENDIX A. EVENT CODES Contact ID Even

Página 14

DE5450P PowerMax Programming Guide 21 Supervisory trouble Zone No.  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1st digit 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 2nd

Página 15 - 7. DEFINING OUTPUT PARAMETERS

22 DE5450P PowerMax Programming Guide APPENDIX B. PROGRAMMABLE ZONE TYPESAPPENDIX B. PROGRAMMABLE ZONE TYPESAPPENDIX B. PROGRAMMABLE ZONE TYPESAPPEND

Página 16 - 7.2 PGM Output Control

DE5450P PowerMax Programming Guide 23 NOTES:

Página 17

24 DE5450P PowerMax Programming Guide EMAIL: [email protected] INTERNET: www.visonic.com VISONIC L

Página 18

DE5450P PowerMax Programming Guide 3 2. SETTING A NEW INSTALLER CODE2. SETTING A NEW INSTALLER CODE2. SETTING A NEW INSTALLER CODE2. SETTING A NEW I

Página 19 - 11.3 Erasing the Event Log

4 DE5450P PowerMax Programming Guide Before anything else, gather up all keyfob units you intend to enroll, and make sure they all have batteries ins

Página 20 - APPENDIX A. EVENT CODES

DE5450P PowerMax Programming Guide 5 4. DEFINING ZONE TYPES4. DEFINING ZONE TYPES4. DEFINING ZONE TYPES4. DEFINING ZONE TYPES 4.1 Preliminary Gu

Página 21

6 DE5450P PowerMax Programming Guide 5 . 2 4 h s i l e n t F. Click <OK> once more to confirm. The “Happy Tune” will sound,

Página 22

DE5450P PowerMax Programming Guide 7 5. DEFINING CONTROL PANEL PARAMETERS5. DEFINING CONTROL PANEL PARAMETERS5. DEFINING CONTROL PANEL PARAMETERS5.

Página 23

8 DE5450P PowerMax Programming Guide Figure 4. DEFINE PANEL Flow Chart

Página 24

DE5450P PowerMax Programming Guide 9 Upon selecting Location 06, the display will change to: 0 6 : A L A R M C A N C E L Select the desired op